Chilled Water Cooling Systems Reports

Cooling Cost-Saving Strategies: Comfort Cooling vs. Precision Cooling
sponsored by Emerson Network Power
WHITE PAPER: Important differences exist between precision cooling and building air conditioning (comfort cooling) in controlling these environmental conditions. In this paper, we compare both cooling systems’ ability to maintain favorable environmental conditions, and their energy efficiency and annual operating costs.
Posted: 11 Oct 2010 | Published: 11 Oct 2010

Emerson Network Power

Humidification Stratiegies for Data Centers and Network Rooms
sponsored by Schneider Electric
WHITE PAPER: This paper explains the nature of humidity, its effects and its management in computer rooms and data centers.
Posted: 26 Mar 2014 | Published: 20 Nov 2008

Schneider Electric

Monitoring the Computer Room's Physical Environment
sponsored by Sensaphone
WHITE PAPER: This paper addresses the greatest environmental threats to the functionality of small to medium computer rooms and presents the time and cost savings associated with the integration of a remote monitoring system.
Posted: 22 Apr 2008 | Published: 22 Apr 2008

Sensaphone

Liebert: The Right Cooling for IT Environments
sponsored by Emerson Network Power
WHITE PAPER: Many IT professionals are finding that dedicated precision cooling is the right solution to provide the ideal environment for sensitive electronics. Read this paper to learn why precision cooling is the optimal choice for keeping data centers cool in the most cost-effective way.
Posted: 13 Jul 2010 | Published: 13 Jul 2010

Emerson Network Power

Intel Xeon Processor 5600 Series
sponsored by Dell, Inc. and Intel®
PRODUCT OVERVIEW: This product overview points out the key constraints on today's infrastructures. Find out how upgrading to multi-core servers can free up space, labor, and power and cooling resources.
Posted: 29 Jun 2011 | Published: 29 Jun 2011

Dell, Inc. and Intel®

Case Study: Arnold Worldwide Enjoys Cost Savings and Scalability
sponsored by DellEMC and Intel®
WHITE PAPER: Arnold Worldwide is a Boston-based global advertising agency. They needed to replace its existing SAN with virtualized storage. Read this case study to learn how Arnold successfully addressed their DR and scalability needs, but also reduced its data center footprint and slashed its power and cooling costs.
Posted: 05 Apr 2012 | Published: 30 Nov 2011

DellEMC and Intel®

Energy Impact of Increased Server Inlet Temperature
sponsored by Schneider Electric
WHITE PAPER: This white paper tests a commonly held idea about the optimal temperature of data center for a variety of infrastructure.
Posted: 09 Oct 2013 | Published: 06 Oct 2011

Schneider Electric

Impact of High Density Hot Aisles on IT Personnel Work Conditions
sponsored by Schneider Electric
WHITE PAPER: This white paper discusses the issue of increasing discomfort for computer room workers in high power density data centers.
Posted: 10 Oct 2013 | Published: 10 Oct 2013

Schneider Electric

Best practices for data center cooling and power management
sponsored by Legrand
EGUIDE: In this expert e-guide from SearchDataCenter.com, learn about the design issues of hot and cold aisle approaches and find out about the tradeoffs of containment. Also, discover why it is necessary to invest in energy-efficient power and cooling for the data center.
Posted: 04 Oct 2011 | Published: 30 Sep 2011

Legrand

Data Center Efficiency Standards: What You Need to Know
sponsored by Hewlett Packard Enterprise
EGUIDE: Discover how your organisation can keep up with data centre energy standards. This e-guide outlines the current expectations and how these might evolve in the future.
Posted: 12 Jun 2012 | Published: 12 Jun 2012

Hewlett Packard Enterprise